- Code: E-01
- Description: Main-M otorLock (CALL SERVICE E01)
- Causes: • Ifno encodersignalis delivered even aftera certain tim e period has elapsed since the m ain m otorbegan running • Ifan overcurrentflows continuouslyfor0.8 sec when the m ain m otor starts running
- Troubleshooting Guides: • Press the <ALL RESET> key.
- Code: E-02
- Description: Elevator-M otorLock (CALL SERVICE E02)
- Causes: • Ifthe upper-lim itsensordoes notcom e on even afterseven seconds has elapsed since the elevatorm otorbegan running in the ascending direction • Ifthe lower-lim itsensordoes notcom e on even afterseven seconds has elapsed since the elevatorm otorbegan running in the descending direction • Ifan overcurrentflows continuouslyfor0.8 sec when the m ain m otor starts running
- Troubleshooting Guides: • Press the <ALL RESET> key. • Turn offthe power and then turn iton again.
- Code: E-03
- Description: Stacker-M otorLock (CALL SERVICE E03)
- Causes: • Ifthe statuses ofthe stackersensorand stackerhom e sensordo not change form ore than one second following the startofoperation of the stackerm otor
- Troubleshooting Guides: • Press the <ALL RESET> key. • Turn offthe power and then turn iton again.
- Code: E-04
- Description: Connection I/F communication error (CALL SERVICE E04)
- Causes: • Ifthe m achine is operated through connection to anotherm achine and an erroroccurs in com m unication with the M asterm achine orSlave m achine
- Troubleshooting Guides: • Turn offthe power and then turn iton again.
- Code: E-05
- Description: Postprocessing-m achine I/F com m unication error (CALL SERVICE E05)
- Causes: • Ifa postprocessing m achine is used and an erroroccurs in com m unication with the postprocessing m achine
- Troubleshooting Guides: • Turn offthe power and then turn iton again.
- Code: E-06
- Description: Stacker-area connection error(CALL SERVICE E06)
- Causes: • Ifthe poweris turned on withoutthe stackerarea connected to the connectorofthe m achine m ain unit
- Troubleshooting Guides: • Press the <ALL RESET> key. • Turn offthe power and then turn iton again.

- Code: E-99
- Description: Maintenance Call (MAINTENANCE E99)
- Causes: • Ifthe m aintenance-collation-countvalue is greaterthan the target m aintenance collation count
- Troubleshooting Guides: • Clearthe countvalue in the testm ode.